key code
Description
Functionality
9
Paddle (Toggle) switch
DOWN - Toggle switch (function depends on currently selected mode)
10
Paddle (Toggle) switch
UP - Toggle switch (function depends on currently selected mode)
11
Paddle (Toggle) switch
DOWN - Toggle switch (function depends on currently selected mode)
12
DVD / VCR
also used to lower control console (in combination with 2 other keys)
13
Elasto
invokes Elastography function
14
Acquisition Mode TD
invokes TD-Mode (Tissue Doppler Mode)
15
Acquisition Mode Contrast
invokes Contrast Imaging function
16
Acquisition Mode XTD
invokes XTD-View (Extended View) function
17
Acquisition Mode BF
invokes B-Flow function
18
Acquisition Mode CW
invokes CW-Mode (Continuous Wave Doppler)
19
Report
call-up of the Patient report page
20
Bodymark
Bodymark display - to enter Bodymark symbols
21
HI
(Coded) Harmonic Imaging
22
Dual Format (V)
Dual-Screen format (vertical distribution)
23
Quad Format
Quad-Screen format
24
Single Format
Single-Screen format
25
Auto (OTO)
Automatic Optimization
26
ABC (Text)
Image Annotation - to write onto the screen
27
Clear
to clear graphics, measurements and annotations on the screen
28
Caliper
Generic Measurements
29
Calc
Calculation (tables)
30
Acquisition Mode 4D
invokes Real Time 4D Mode (continuous volume sweep)
31
Acquisition Mode 3D
invokes 3D Volume Mode
32
Depth (Toggle) switch
Penetration Depth UP - Toggle switch function
33
Depth (Toggle) switch
Penetration Depth DOWN - Toggle switch function
34
Focus Depth (Toggle) switch
Focus Depth UP - Toggle switch function
35
Focus Depth (Toggle) switch
Focus Depth DOWN - Toggle switch function
36
Trackball pointer
displays a pointer (arrow or hand shaped cursor)
37
P2
programmable key
38
P4
programmable key
39
Exit
Exit current menu
40
P1
programmable key
41
P3
programmable key
42
Trackball Mode switch
function depends on currently selected mode
43
Trackball Mode switch
function depends on currently selected mode
44
Trackball Mode switch
function depends on currently selected mode
45
Freeze
Read/Write (Freeze/Run)
46
Encoder 1
function depends on currently selected mode
47
Encoder 2
function depends on currently selected mode
48
Encoder 3
function depends on currently selected mode
Components and Functions (Theory)
5-30
Voluson E-Series Service Manual
KTD106657 Revision 2
Содержание H48681XB
Страница 11: ...Introduction Voluson E Series Service Manual KTD106657 Revision 2 1 3 ...
Страница 12: ...Introduction 1 4 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 13: ...Introduction Voluson E Series Service Manual KTD106657 Revision 2 1 5 ...
Страница 14: ...Introduction 1 6 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 15: ...Introduction Voluson E Series Service Manual KTD106657 Revision 2 1 7 ...
Страница 16: ...Introduction 1 8 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 17: ...Introduction Voluson E Series Service Manual KTD106657 Revision 2 1 9 ...
Страница 36: ...This page was intentionally left blank Introduction 1 28 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 172: ...This page was intentionally left blank Functional Checks 4 46 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 226: ...This page was intentionally left blank Service Adjustments 6 8 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 288: ...This page was intentionally left blank Replacement Procedures 8 30 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 364: ...This page was intentionally left blank Care and Maintenance 10 24 Voluson E Series Service Manual KTD106657 Revision 2 ...
Страница 365: ......
Страница 366: ...GE Healthcare Austria GmbH Co OG Tiefenbach 15 4871 Zipf Austria www gehealthcare com ...