GE Multilin
D60 Line Distance Protection System
C-27
APPENDIX C
C.7 LOGICAL NODES
C
ITPC: Teleprotection communication interfaces
---
K: LOGICAL NODES FOR MECHANICAL AND NON-ELECTRIC PRIMARY EQUIPMENT
KFAN: Fan
---
KFIL: Filter
---
KPMP: Pump
---
KTNK: Tank
---
KVLV: Valve control
---
M: LOGICAL NODES FOR METERING AND MEASUREMENT
MENV: Environmental information
---
MFLK: Flicker measurement name
---
MHAI: Harmonics or interharmonics
---
MHAN: Non phase related harmonics or interharmonics
---
MHYD: Hydrological information
---
MMDC: DC measurement
---
MMET: Meteorological information
---
MMTN: Metering
---
MMTR: Metering
---
MMXN: Non-phase-related measurement
Yes
MMXU: Measurement
Yes
MSQI: Sequence and imbalance
Yes
MSTA: Metering statistics
---
P: LOGICAL NODES FOR PROTECTION FUNCTIONS
PDIF: Differential
Yes
PDIR: Direction comparison
---
PDIS: Distance
Yes
PDOP: Directional overpower
---
PDUP: Directional underpower
---
PFRC: Rate of change of frequency
---
PHAR: Harmonic restraint
---
PHIZ: Ground detector
---
PIOC: Instantaneous overcurrent
Yes
PMRI Motor restart inhibition
---
PMSS: Motor starting time supervision
---
POPF: Over power factor
---
PPAM: Phase angle measuring
---
PRTR: Rotor protection
---
PSCH: Protection scheme
---
PSDE: Sensitive directional earth fault
---
PTEF: Transient earth fault
---
PTOC: Time overcurrent
Yes
PTOF: Overfrequency
---
PTOV: Overvoltage
Yes
PTRC: Protection trip conditioning
Yes
PTTR: Thermal overload
---
PTUC: Undercurrent
---
PTUF: Underfrequency
---
PTUV: Undervoltage
Yes
Table C–1: IEC 61850 LOGICAL NODES (Sheet 2 of 4)
NODES
UR-FAMILY
Содержание D60
Страница 61: ...GE Multilin D60 Line Distance Protection System 2 31 2 PRODUCT DESCRIPTION 2 3 SPECIFICATIONS 2 ...
Страница 62: ...2 32 D60 Line Distance Protection System GE Multilin 2 3 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 102: ...3 40 D60 Line Distance Protection System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 134: ...4 32 D60 Line Distance Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 508: ...5 374 D60 Line Distance Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 538: ...6 30 D60 Line Distance Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 610: ...10 8 D60 Line Distance Protection System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Страница 622: ...A 12 D60 Line Distance Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 745: ...GE Multilin D60 Line Distance Protection System B 123 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 746: ...B 124 D60 Line Distance Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 776: ...C 30 D60 Line Distance Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 792: ...E 10 D60 Line Distance Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 804: ...F 12 D60 Line Distance Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 826: ...xii D60 Line Distance Protection System GE Multilin INDEX ...