14. EXPLANATION OF SYMBOLS AND STORAGE
Keep away from sunlight
High intensity light
Keep dry
Refer to instruction manual / booklet
Fragile. Handle with care.
Attention, see instructions for use
45°C
-20°C
Temperature limitations:
-20°C to +45°C
Please do not discard this device in household
garbage.
(See “Disposal” section above)
95%
10%
Humidity limitation:
10 % to 95 %
relative humidity
Handpiece sleeve & light-guide:
Sterilizable in a steam sterilizer (autoclave) at
134°C
106 kPa
50 kPa
Atmospheric pressure limitations:
50 kPa to 106 kPa
CE marking of conformity
15. CONTACT INFORMATION
In case of any questions, please contact the GC Europe dealer/importer from which the product was purchased.
Manufacturer
GC Europe N.V
Researchpark Haasrode-Leuven 1240
Interleuvenlaan 33
B-3001 Leuven, Belgium
16. EMC TABLES
The D-Light Pro is intended for use in the electromagnetic environment specifi ed below. The customer or the user of the
D-Light Pro should ensure that it is used in such an environment.
Guidance and manufacturer’s declaration – Electromagnetic emissions
EN 60601 – 1-2 / Tabel 201
RF emissions CISPR 11
Group 1
The D-Light Pro uses RF energy only for its internal function.
Therefore its RF emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
RF emissions CISPR 11
Class B
The D-Light Pro is suitable for use in all establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings
used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Complies
Voltage fl uctuations / fl icker
emissions IEC 61000-3-3
Complies
Guidance and manufacturer’s declaration – Electromagnetic immunity
EN 60601 – 1-2 / Table 202
Immunity test
Test level
Compliance
Electromagnetic environment guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
±6 kV contact
±8 kV air
The device continues
to work regularly and
in safety.
Floors should be wood, concrete or ceramic
tile. If fl oors are covered with synthetic material,
the relative humidity should be at least 30%.
Radiated RF
IEC 61000-4-3
3 V/m 80 Mhz to 2.5 GHz
The device continues
to work regularly and
in safety
Field strengths from fi xed transmitters cannot
be predicted theoretically with accuracy. To
assess the electromagnetic environment due
to fi xed RF transmitters, an electromagnetic
site survey should be considered.
Electrical fast
transient / burst
IEC 61000-4-4
±2 kV for power supply
lines
±1 kV for input / output
lines
The device continues
to work regularly and
in safety
Mains power quality should be that of a typical
commercial or hospital environment.
Surge
IEC 610004-5
±1 kV diff erential mode
±2 kV common mode
The device continues
to work regularly and
in safety.
Conducted RF
IEC 61000-4-6
3 Veff 150 kHz to 80 MHz
The device continues
to work regularly and
in safety.
Portable and mobile RF communications
equipment should be used no closer to any
part of the disposal, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
Recommended separation distance1):
d = 1.2 √P
d = 1.2 √P 80 MHz to 800 Mhz
d = 2.3 √P 800 MHz to 2.5 GHz
Power frequency
(50/60 Hz) magnetic
fi eld IEC 61000
3-100 A/m
The device continues
to work regularly and
in safety.
Power frequency magnetic fi elds should be at
levels characteristic of a typical location in a
typical commercial or hospital environment.
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
<5% U/10ms
70% U/ 0.5s
40% U/0.1s
The device can vary
from the required
levels of immunity
with a duration for as
long as the device
remains in safety; no
malfunctions have
been detected and
can be restored to
pre-test status with
the intervention of
the operator.
Mains power quality should be that of a typical
commercial or hospital environment.
EN
DE
FR
IT
ES
NL
DA
SV
NO
PT
FI
EL
EN
BG
CS
HR
HU
PL
RO
RU
SK
SL
SR
UK
TR
LV
LT
ET
406950-GC-D-LIGHT DUO-IFU-OOST ok.indd 9
13/10/16 15:57
Содержание D-Light Pro
Страница 16: ...16 8 3 3 9 10 3 12 GC Europe 406950 GC D LIGHT DUO IFU OOST ok indd 16 13 10 16 15 57...
Страница 82: ...82 EN 13060 2004 A2 2010 S 8 3 LED 406950 GC D LIGHT DUO IFU OOST ok indd 82 13 10 16 15 57...
Страница 124: ...124 8 3 9 10 3 12 GC Europe 406950 GC D LIGHT DUO IFU OOST ok indd 124 13 10 16 15 57...
Страница 130: ...130 1 2 3 2 4 5 6 7 8 9 10 11 12 c 360 13 14 20 10 15 16 406950 GC D LIGHT DUO IFU OOST ok indd 130 13 10 16 15 57...