FastIron Hardware Installation Guide for the FSX, FSX 800, and FSX 1600
5 - 18
© 2008 Foundry Networks, Inc.
December 2008
The following shows an example of the
show chassis
command output on the FSX 800. The display is similar on
the FSX 1600. This display shows the currently configured temperature thresholds for the management
module(s) (Rule 1/3), all of the interface modules (Rule 2/3), and the switch fabric modules (Rule 3/3).
Syntax:
show chassis
Shutdown Warning Messages
If any thermal plane exceeds the shutdown temperature level, the Foundry device will display a shutdown warning
message on the console every five seconds until either the temperature level goes back down below the shutdown
temperature level, or the system shuts down the chassis to prevent further damage (shutdown occurs after five
minutes of exceeding the shutdown temperature level).
The shutdown warning messages indicate the thermal plane that triggered the warning and the number of
seconds before the device will shut down. The following shows an example warning message:
!!! Temperature of SWITCH FABRIC CARDS THERMAL PLANE is over shutdown level, system
is going to be shutdown in 300 seconds !!!
Changing the Temperature Warning Level (Pre-03.0.00)
NOTE:
The
temperature warning
CLI command was deprecated in software release 03.0.00, since the new fan
speed-related messages and traps provide adequate warning of rising temperatures.
In software releases prior to 03.0.00, you can change the temperature at which the device sends a temperature
warning message. The valid range is 0 – 125 degrees Celsius.
The Foundry device compares the exhaust side temperature reading on the management module with the
configured warning temperature. If the temperature exceeds the configured warning temperature, the system
generates a warning message.
NOTE:
You cannot set the warning temperature to a value higher than the shutdown temperature.
To change the temperature at which the device will send a warning message, enter a command such as the
following at the Privileged EXEC level of the CLI:
FastIron# temperature warning 47
FastIron# show chassis
...
Fan speed switching temperature thresholds:
Rule 1/3 (MGMT CARDS THERMAL PLANE):
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
Rule 2/3 (LINE CARDS THERMAL PLANE):
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE)***active***:
Speed 1: NM<----->57 deg-C
Speed 2: 48<----->58 deg-C
Speed 3: 49<----->59 deg-C
Speed 4: 50<----->80 deg-C (shutdown)
...
Содержание FastIron SuperX
Страница 139: ...Maintaining the Hardware December 2008 2008 Foundry Networks Inc 7 25 AC1 AC2 AC3 AC4 Cord Retainer Cord Retainer...
Страница 148: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 7 34 2008 Foundry Networks Inc December 2008...
Страница 168: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 8 20 2008 Foundry Networks Inc December 2008...
Страница 198: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 C 16 2008 Foundry Networks Inc December 2008...