FastIron Hardware Installation Guide for the FSX, FSX 800, and FSX 1600
5 - 8
© 2008 Foundry Networks, Inc.
December 2008
Temperature Readings
Fan controlled temperature
The FSX displays the temperature reading of the management and
interface modules:
•
Rule 1/2 – The temperature reading of the management module.
•
Rule 2/2 – In releases prior to 03.0.00, this field displays the average
temperature reading of all the interface modules. In releases 03.0.00
and later, this field displays the
highest
temperature reading of all the
interface modules.
The FSX 800 and FSX 1600 display the temperature reading of the
management, interface, and switch fabric modules:
•
Rule 1/3 – The highest temperature reading of the management
module(s).
•
Rule 2/3 – The highest temperature reading of all the interface
modules.
•
Rule 3/3 – The highest temperature reading of the switch fabric
modules.
Fan speed switching temperature
thresholds
The FSX displays the configured temperature thresholds for the
management and interface modules.
•
Rule 1/2 (MGMT CARDS THERMAL PLANE) – The configured
temperature threshold for the management module.
•
Rule 2/2 – (LINE CARDS THERMAL PLANE) – The configured
temperature thresholds for the interface modules.
The FSX 800 and FSX 1600 display the configured temperature
thresholds for the management, interface, and switch fabric modules.
•
Rule 1/3 (MGMT CARDS THERMAL PLANE) – The configured
temperature thresholds for the management module(s).
•
Rule 2/3 – (LINE CARDS THERMAL PLANE) – The configured
temperature thresholds for all the interface modules.
•
Rule 3/3 – (SWITCH FABRIC CARDS THERMAL PLANE) – The
configured temperature thresholds for the switch fabric modules.
The output displays fan speed information for each of the above thermal
planes:
In releases 03.0.00 and later, the FSX and FSX 800 chassis devices have
four fan speeds as illustrated in Figure 5.2 on page 5-15.
In releases prior to 03.0.00 and for the FSX 1600, there are five fan
speeds as illustrated in Figure 5.1 on page 5-11.
Slot <number> Temperature
The temperature of each module.
•
On the FSX, the management module resides in slot 9. In software
releases prior to 03.0.00, the report includes the exhaust side and
intake side temperatures.
•
On the FSX 800 and FSX 1600, the management modules reside in
slots 9 and 10 and the switch fabric modules are
SF 1
and
SF 2
.
Table 5.1: Chassis Status and Temperature Information (Continued)
This Field...
Displays...
Содержание FastIron SuperX
Страница 139: ...Maintaining the Hardware December 2008 2008 Foundry Networks Inc 7 25 AC1 AC2 AC3 AC4 Cord Retainer Cord Retainer...
Страница 148: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 7 34 2008 Foundry Networks Inc December 2008...
Страница 168: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 8 20 2008 Foundry Networks Inc December 2008...
Страница 198: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 C 16 2008 Foundry Networks Inc December 2008...