Product Overview
December 2008
© 2008 Foundry Networks, Inc.
2 - 21
CAUTION:
It is recommended that modules be disabled through the CLI before removal from the
chassis. If the operator wishes to remove the module without first disabling the module, the
Enhanced Hot Swap capability in software Release 03.2.00 and later supports this procedure
for the FastIron SX 800 and FastIron SX 1600 chassis. Enhanced Hot Swap (that is, no CLI
disable
) should be performed during a maintenance window. On rare occasions, an
Enhanced Hot Swap may result in a software reload of the system. The likelihood of this event
is very low.
It is important to wait a minimum of 10 seconds between the removal and insertion of a line
module. Re-insertion of a line module less than 10 seconds after the removal of a line module
may result in the line module not being properly recognized.
See “Replacing an Interface Module” on page 7-7 for instructions.
24-port Gigabit Ethernet Copper Interface Module
The 24-port Gigabit Ethernet Copper interface module has 24 10/100/1000 ports with RJ-45 connectors for Cat5
cabling. The copper ports support automatic MDI/MDIX detection, and use auto-sensing and auto-negotiating to
determine the speed (10, 100, or 1000 Mbps) and duplex mode (full-duplex or half-duplex) of the port at the other
end of the link, and adjust the port accordingly. Note that ports operating at 1000 Mbps operate in the full-duplex
mode only and cannot be modified.
The 24-port Gigabit Ethernet Copper Interface module supports Power over Ethernet (POE). You can either order
the interface module with POE capability, or upgrade your existing 24-port Gigabit Ethernet Copper module by
installing a POE daughter card. To run POE on your system, you must also install at least one 48-volt power
supply.
NOTE:
Instructions for installing a POE daughter card are provided in “Installing or Replacing a POE Daughter
Figure 2.15 shows the front panel of the IPv4 24-port Gigabit Ethernet copper module.
Figure 2.15
IPv4 24-port Gigabit Ethernet Copper Module Front Panel
Figure 2.16 shows the front panel of the IPv6 24-port Gigabit Ethernet copper module.
Figure 2.16
IPv6 24-port Gigabit Ethernet Copper Module Front Panel
424C
Port 1
Port 2
Port 1
3
Port 24
Port 14
POE LED
s
624C
Port 1
Port 2
Port 1
3
Port 24
Port 14
POE LED
s
Содержание FastIron SuperX
Страница 139: ...Maintaining the Hardware December 2008 2008 Foundry Networks Inc 7 25 AC1 AC2 AC3 AC4 Cord Retainer Cord Retainer...
Страница 148: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 7 34 2008 Foundry Networks Inc December 2008...
Страница 168: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 8 20 2008 Foundry Networks Inc December 2008...
Страница 198: ...FastIron Hardware Installation Guide for the FSX FSX 800 and FSX 1600 C 16 2008 Foundry Networks Inc December 2008...