Using a Redundant Management Module
December 2008
© 2008 Foundry Networks, Inc.
6 - 13
Displaying Temperature Information
Each management module contains two temperature sensors. By default, the system polls the temperature of
each management module every 60 seconds. You can display the current temperature of the management
modules (and all other modules) by entering the following command at any CLI level:
Syntax:
show chassis
The output displays the temperature of the management modules. For information about all output generated by
the
show chassis
command, see “Displaying Chassis Status and Temperature Readings” on page 5-1.
Displaying Switchover Information
You can view the system log or the traps logged on an SNMP trap receiver, which includes Information about
whether a switchover has occurred. See also “Syslog Message for Hitless OS Upgrade and Hitless Switchover”
on page 6-7.
FastIron# show chassis
...
Slot 9 Temperature: 31.0 deg-C
Slot 10 Temperature: 34.0 deg-C
...