appendix c
dip switch settings
DIP switches are located on the back panel of the
PSC and RSC. To change the
DIP switch settings remove the clear panel and set switches. The
ESCS reads
DIP switch settings when the unit is turned on. If you change any settings, you
must restart console before the new settings will take effect.
Switches in the down position are off; switches in the up position are on
. The
PSC and RSC do not use DIP switches A1, A2, and A5.
DIP switch B8 must be
Off when you start the system.
Messages
A3
ETC messages
Off
ARRI messages
On
CRT AC line frequency
A4
60 Hz
Off
50 Hz
On
Manual readback
A6
A7
A8
None
Off
Off
Off
32 channels
Off
Off
On
64 channels
Off
On
Off
96 channels
Off
On
On
192 channels
On
Off
Off
Analog dimmer outputs
B1
B2
96 wire per dimmer outputs
Off
Off
192 wire per dimmer outputs
Off
On
Strand 192 AMX192 Multiplex outputs
On
Off
Strand 384 AMX192 Multiplex outputs
On
On
Digital dimmer outputs
B3
DMX 512 output
Off
Redundant tracking†
B4
B5
Redundant tracking on
On
Redundant tracking off
Off
Master console
Off
Slave console
On
†Set printer to parallel
Face panel diagnostics‡
B6
Enabled
On
Disabled
Off
‡Displays timeout message