Operating Instructions
J22 TDLAS Gas Analyzer
40
Hauser
Functional role/Menu
User Role and Tasks
Content/Meaning
Task
Oriented
Display
Language
Role Operator, Maintenance
Tasks during operation:
•
Configuring the
operational display
•
Reading measured values
•
Defining the operating language
•
Defining the web server operating language
Operation
•
Configuring the operational display (e.g.,
display format)
Setup
Maintenance role
Commissioning:
•
Configuration of the
measurement
•
Configuration of the
inputs and outputs
•
Configuration of the
communication interface
Wizards for fast commissioning:
•
Set the system units
•
Configuration of the communication interface
•
Display I/O configuration
•
Configure the inputs and outputs
•
Configuring the operational display
•
Define the output conditioning
Advanced setup
•
For more customized configuration of the
measurement (adaptation to special
measuring conditions)
•
Administration (define access code, reset
measuring device)
Diagnostics
Maintenance role
Fault elimination:
•
Diagnostics and
elimination of process
and device errors
•
Measured value
simulation
Contains all parameters for error detections and
analyzing process errors:
•
Diagnostic list.
Contains up to 5 currently
pending diagnostics messages.
•
Event logbook.
Contains event messages that
have occurred.
•
Device information.
Contains information for
identifying the device.
•
Measured values.
Contains all current
measured values.
•
Data logging submenu.
Storage and
visualization of measured values
•
Heartbeat technology.
The functionality of
the device is checked on demand and the
verification results are documented.
•
Simulation.
Is used to simulate measured
values or output values.
Function
Oriented
Expert
Tasks that require detailed
knowledge of the function of the
device:
•
Commissioning
measurements under
difficult conditions
•
Optimal adaptation of
the measurement to
difficult conditions
•
Error diagnostics in
difficult cases
•
Detailed configuration of
the communication
interface
Contains all the parameters of the device. The structure
of this menu is based on the function blocks of the
device:
•
System.
Contains all higher-order device
parameters that do not concern the
measurement or the communication interface.
•
Sensor.
Configuration of the measurement.
•
Output.
Configuration of the analog current
outputs and switch outputs.
•
Input.
Configuration of the analog current
inputs.
•
Communication.
Configuration of the digital
communication interface and the web server.
•
Diagnostics.
Error detection and analysis of
process and device errors, and for device
simulation and Heartbeat Technology.