13 – 3
Section 13
•
Instruments Calibration
Vission 20/20 • Operation and Service Manual • Emerson • 35391SC 2.7
much as possible. In addition, the operator will need to
enter a value into the “Enter Desired Value” entry box
that is equal to the measured value in amps by a cali-
brating measurement device. After entering the mea-
sured value, the displayed motor current may still be off
slightly. In this case re-enter the desired value and the
displayed value should get progressively closer.
4-20mA Scale:
• 4mA:
•
Not editable by the operator. Defines the
minimum value in amps represented by a 4mA
input.
• 20mA:
•
Defines the maximum value in amps repre
-
sented by a 20mA input.
• Enter Desired Value:
• The operator enters the correct current value.
Each entry will recalculate the point-slope calcu-
lations of the current calibration.
• Total Error:
• Not editable by the operator. Displays the
total error offset of the entries from the “Enter
Desired Value” setpoint.
Current Transformer Ratio:
• Primary
•
Defines the upper value of the current
transformer.
• Secondary:
•
Not editable by the operator. Defines the
minimum value of the current transformer.
• Enter Desired Value:
• The operator enters the value of the cor-
rect current value. Each entry will recalculate
the point-slope calculations of the current
calibration.
• Total Error:
• Not editable by the operator. Displays the to-
tal error offset of entries from the “Enter Desired
Value” setpoint.
Figure 13-3. Instruments Calibration Screen - Process Temperature (Page 3)
Содержание Vilter Vission 20/20
Страница 1: ...Vission 20 20TM Micro controller Operation and service manual Version 2 7 ...
Страница 2: ......
Страница 4: ......
Страница 220: ...B 2 Blank Vission 20 20 Operation and Service Manual Emerson 35391SC 2 7 ...
Страница 300: ...D 2 Blank Vission 20 20 Operation and Service Manual Emerson 35391SC 2 6 ...
Страница 336: ......
Страница 337: ......