Chapter 26
| CFM Commands
Continuity Check Operations
– 793 –
Continuity Check Operations
ethernet cfm cc ma
interval
This command sets the transmission delay between continuity check messages
(CCMs). Use the
no
form to restore the default settings.
Syntax
ethernet cfm cc md
domain-name
ma
ma-name
interval
interval-level
no ethernet cfm cc ma
ma-name
interval
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
ma-name –
Maintenance association name. (Range: 1-43 alphanumeric
characters)
interval-level –
The transmission delay between connectivity check
messages. The setting for this parameter is expressed as levels 4 through 7,
which in turn map to specific intervals of time. (CCM interval field options:
4 - 1 second, 5 - 10 seconds, 6 - 1 minute, 7 - 10 minutes)
Default Setting
4 (1 second)
Command Mode
Global Configuration
Command Usage
◆
CCMs provide a means to discover other MEPs and to detect connectivity
failures in an MA. If any MEP fails to receive three consecutive CCMs from any
other MEPs in its MA, a connectivity failure is registered. The interval at which
Port State
Port states include:
Up – The port is functioning normally.
Blocked – The port has been blocked by the Spanning Tree Protocol.
No port state – Either no CCM has been received, or nor port status TLV
was received in the last CCM.
Interface State
Interface states include:
No Status – Either no CCM has been received, or no interface status TLV
was received in the last CCM.
Up – The interface is ready to pass packets.
Down – The interface cannot pass packets.
Testing – The interface is in some test mode.
Unknown – The interface status cannot be determined for some reason.
Dormant – The interface is not in a state to pass packets but is in a pending
state, waiting for some external event.
Not Present – Some component of the interface is missing.
isLowerLayerDown – The interface is down due to state of the lower layer
interfaces.
Crosscheck Status
Shows if crosscheck function has been enabled.
Table 160: show ethernet cfm maintenance-points remote detail - display
Field
Description
Содержание ECS4120-28F
Страница 36: ...Contents 36...
Страница 38: ...Figures 38...
Страница 46: ...Section I Getting Started 46...
Страница 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Страница 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Страница 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 216: ...Chapter 7 Flow Sampling Commands 216...
Страница 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Страница 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Страница 384: ...Chapter 10 Access Control Lists ACL Information 384...
Страница 424: ...Chapter 11 Interface Commands Power Savings 424...
Страница 446: ...Chapter 13 Power over Ethernet Commands 446...
Страница 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Страница 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Страница 494: ...Chapter 18 Address Table Commands 494...
Страница 554: ...Chapter 20 ERPS Commands 554...
Страница 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Страница 638: ...Chapter 23 Quality of Service Commands 638...
Страница 772: ...Chapter 25 LLDP Commands 772...
Страница 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...
Страница 826: ...Chapter 27 OAM Commands 826 1 1 00 12 CF 6A 07 F6 000084 Enabled Disabled Enabled Disabled Console...
Страница 836: ...Chapter 28 Domain Name Service Commands 836...
Страница 848: ...Chapter 29 DHCP Commands DHCP Relay Option 82 848...
Страница 902: ...Section III Appendices 902...
Страница 916: ...Glossary 916...
Страница 926: ...CLI Commands 926...
Страница 937: ......
Страница 938: ...E092017 CS R02...