Chapter 5
| SNMP Commands
SNMP Target Host Commands
– 185 –
◆
The
snmp-server host
command is used in conjunction with the
command to enable
the sending of traps or informs and to specify which SNMP notifications are
sent globally. For a host to receive notifications, at least one
command and the
snmp-server host
command for that host
must be enabled.
◆
Some notification types cannot be controlled with the
command. For example, some notification types are always
enabled.
◆
Notifications are issued by the switch as trap messages by default. The recipient
of a trap message does not send a response to the switch. Traps are therefore
not as reliable as inform messages, which include a request for
acknowledgement of receipt. Informs can be used to ensure that critical
information is received by the host. However, note that informs consume more
system resources because they must be kept in memory until a response is
received. Informs also add to network traffic. You should consider these effects
when deciding whether to issue notifications as traps or informs.
To send an inform to a SNMPv2c host, complete these steps:
1.
Enable the SNMP agent (
2.
Create a view with the required notification messages (
3.
Create a group that includes the required notify view (
4.
Allow the switch to send SNMP traps; i.e., notifications (
).
5.
Specify the target host that will receive inform messages with the
snmp-
server host
command as described in this section.
To send an inform to a SNMPv3 host, complete these steps:
1.
Enable the SNMP agent (
2.
Create a remote SNMPv3 user to use in the message exchange process
(
).
3.
Create a view with the required notification messages (
4.
Create a group that includes the required notify view (
5.
Allow the switch to send SNMP traps; i.e., notifications (
).
6.
Specify the target host that will receive inform messages with the
snmp-
server host
command as described in this section.
◆
The switch can send SNMP Version 1, 2c or 3 notifications to a host IP address,
depending on the SNMP version that the management station supports. If the
snmp-server host
command does not specify the SNMP version, the default is
to send SNMP version 1 notifications.
◆
If you specify an SNMP Version 3 host, then the community string is interpreted
as an SNMP user name. The user name must first be defined with the
command. Otherwise, an SNMPv3 group will be automatically
created by the
snmp-server host
command using the name of the specified
community string, and default settings for the read, write, and notify view.
Содержание ECS4120-28F
Страница 36: ...Contents 36...
Страница 38: ...Figures 38...
Страница 46: ...Section I Getting Started 46...
Страница 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Страница 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Страница 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 216: ...Chapter 7 Flow Sampling Commands 216...
Страница 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Страница 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Страница 384: ...Chapter 10 Access Control Lists ACL Information 384...
Страница 424: ...Chapter 11 Interface Commands Power Savings 424...
Страница 446: ...Chapter 13 Power over Ethernet Commands 446...
Страница 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Страница 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Страница 494: ...Chapter 18 Address Table Commands 494...
Страница 554: ...Chapter 20 ERPS Commands 554...
Страница 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Страница 638: ...Chapter 23 Quality of Service Commands 638...
Страница 772: ...Chapter 25 LLDP Commands 772...
Страница 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...
Страница 826: ...Chapter 27 OAM Commands 826 1 1 00 12 CF 6A 07 F6 000084 Enabled Disabled Enabled Disabled Console...
Страница 836: ...Chapter 28 Domain Name Service Commands 836...
Страница 848: ...Chapter 29 DHCP Commands DHCP Relay Option 82 848...
Страница 902: ...Section III Appendices 902...
Страница 916: ...Glossary 916...
Страница 926: ...CLI Commands 926...
Страница 937: ......
Страница 938: ...E092017 CS R02...