Chapter 26
| CFM Commands
Defining CFM Structures
– 784 –
ethernet cfm mep
This command sets an interface as a domain boundary, defines it as a maintenance
end point (MEP), and sets direction of the MEP in regard to sending and receiving
CFM messages. Use the
no
form to delete a MEP.
Syntax
ethernet cfm mep mpid
mpid
md
domain-name
ma
ma-name
[
up
]
no ethernet cfm mep mpid
mpid
ma
ma-name
mpid –
Maintenance end point identifier. (Range: 1-8191)
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
ma-name –
Maintenance association name. (Range: 1-43 alphanumeric
characters)
up
–
Indicates that the MEP faces inward toward the switch cross-connect
matrix, and transmits CFM messages towards, and receives them from, the
direction of the internal bridge relay mechanism. If the
up
keyword is not
included in this command, then the MEP is facing away from the switch,
and transmits CFM messages towards, and receives them from, the
direction of the physical medium.
Default Setting
No MEPs are configured.
The MEP faces outward (down).
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
◆
CFM elements must be configured in the following order: (1) maintenance
domain at the same level as the MEP to be configured (using the
command), (2) maintenance association within the domain (using the
command), and (3) finally the MEP using this command.
◆
An interface may belong to more than one domain. This command can be used
to configure an interface as a MEP for different MAs in different domains.
◆
To change the MEP’s MA or the direction it faces, first delete the MEP, and then
create a new one.
Example
This example sets port 1 as a DSAP for the specified maintenance association.
Console(config)#interface ethernet 1/1
Console(config-if)#ethernet cfm mep mpid 1 md voip ma rd
Console(config-if)#
Содержание ECS4120-28F
Страница 36: ...Contents 36...
Страница 38: ...Figures 38...
Страница 46: ...Section I Getting Started 46...
Страница 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Страница 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Страница 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 216: ...Chapter 7 Flow Sampling Commands 216...
Страница 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Страница 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Страница 384: ...Chapter 10 Access Control Lists ACL Information 384...
Страница 424: ...Chapter 11 Interface Commands Power Savings 424...
Страница 446: ...Chapter 13 Power over Ethernet Commands 446...
Страница 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Страница 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Страница 494: ...Chapter 18 Address Table Commands 494...
Страница 554: ...Chapter 20 ERPS Commands 554...
Страница 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Страница 638: ...Chapter 23 Quality of Service Commands 638...
Страница 772: ...Chapter 25 LLDP Commands 772...
Страница 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...
Страница 826: ...Chapter 27 OAM Commands 826 1 1 00 12 CF 6A 07 F6 000084 Enabled Disabled Enabled Disabled Console...
Страница 836: ...Chapter 28 Domain Name Service Commands 836...
Страница 848: ...Chapter 29 DHCP Commands DHCP Relay Option 82 848...
Страница 902: ...Section III Appendices 902...
Страница 916: ...Glossary 916...
Страница 926: ...CLI Commands 926...
Страница 937: ......
Страница 938: ...E092017 CS R02...