Operating Instructions
Commissioning
© Copyright by Markem-Imaje CSAT GmbH
ITS6_135_Manual_EN.doc
Subject to Technical Modifications
Page 237 / 370
7.4
Function test
Caution
Potential danger due to incorrect rotation of motors.
Before a general function test is performed on the machine, check
the direction of rotation on the individual motors.
Information
The general function test should start first with a comprehensive test of
all manual functions before changing to automatic mode.
Test
No.
Prerequisite /
Criterion
Expected reaction of the print-
er
:
If something else
occurs:
1
Turn the main
switch and the
ON/OFF switch
of the printer to
“I” position.
The printer’s internal computer
will boot.
The touchscreen of the printer’s
control panel will display the
home page.
The printer will not start running
unchecked on its own.
Processes cannot be started until
the operator has logged in with a
password.
Is the required voltage
being supplied?
Did a fuse blow?
Check cable connec-
tions.
2
Test of the door
monitors:
Open any one
of the moni-
tored shrouds
or doors
Safety interlocks can only be
released when the printer is shut
down.
When doors are open, a mes-
sage is displayed in the top line
of the touchscreen. A separate
message is displayed for each
door that it is open:
5 Bottom left door open
12 Bottom right door open
63 Printing unit: Shroud open
66 Rear door open
Neither the printer nor the partner
machine can be started as long
as doors are open.
Check whether the
doors are equipped
with safety switches.
Check the wiring of
the safety switches.
Is the required voltage
being supplied?