Operating Instructions
Troubleshooting
© Copyright by Markem-Imaje CSAT GmbH
ITS6_135_Manual_EN.doc
Subject to Technical Modifications
Page 267 / 370
Code Display:
CA = Current Alarm;
S= Status
M
essage
or
A
larm?
C
ause of the message /
R
emedial action:
To be
elimin.
by
43
CA "43= Main curing
2: Error“
A
C: The temperature of the middle main curing
module is too high. The LEDs of this module
will be switched off automatically.
S, C
S:
"30= Printer not
ready for START"
R: In the touchscreen tab
Job > UV Curing,
turn
off the "UV power supply unit," wait 10 sec-
onds and turn it back on.
If the alarm nos. 42 - 44 should continue to
appear frequently: Call a service technician
or the CSAT customer service.
44
CA "44= Main curing
3: Error“
A
C: The temperature of the bottom main curing
module is too high. The LEDs of this module
will be switched off automatically.
S, C
S:
"30= Printer not
ready for START"
R: In the touchscreen tab
Job > UV Curing,
turn
off the "UV power supply unit," wait 10 sec-
onds and turn it back on.
If the alarm nos. 42 - 44 should continue to
appear frequently: Call a service technician
or the CSAT customer service.
45
CA "45= Main curing
power supply unit
1: Error"
A
C: Disturbance/interruption in power supply to
lamp 1
S, C
S:
"30= Printer not
ready to START"
R: Please check: Was the motor circuit breaker
+300-QM1 triggered? Did at least one of the
power supply units +300-
G10…-G12 fail?
Are the lines damaged or contacts loose?
46
"46= Main curing
power supply unit
2: Error"
A
C: Disturbance/interruption in power supply to
lamp 2
S, C
S:
"30= Printer not
ready to START"
R: Please check: Was the motor circuit breaker
+300-QM3 triggered? Did at least one of the
power supply units +300-
G20…-G22 fail?
Are the lines damaged or contacts loose?
47
CA "47= Main curing
power supply unit
3: Error"
A
C: Disturbance/interruption in power supply to
lamp 3
S, C
S:
"30= Printer not
ready to START"
R: Please check: Was the motor circuit breaker
+300-QM5 triggered?
Did at least one of the power supply units
+300-
G30…-G32 fail?
Are the lines damaged or contacts loose?