6.2
Installation of the printer’s supply systems
Warning
Installation of the supply lines.
The printer must be connected properly to all supply lines by quali-
fied technical personnel.
The commissioning procedure should be carried out in accordance
with the operating instructions only.
6.2.1
Electrical connection
The ITS6 printer must be connected properly to the power supply with the
correct voltage and frequency.
>
Plug the lead of the printer into a compatible and fuse-protected socket
of the three-phase current supply network.
(Observe specifications on the type plate of the printer!)
6.2.2
Pneumatic system
All of the pneumatic equipment on the ITS6 printer is pre-installed.
The ITS6 printer requires dry, oil-free air.
Flow rate and pressure are maximum 10 dm³/min and 6
– 8 bar respective-
ly.
>
Connect the line coming from the on-site compressed air supply to the
coupling plug on the printer.
>
Check for leaks and the secure fit of all hose connections.
Notice
Make sure to connect a pneumatic supply line with a 2’’ diameter and
permanent excess pressure of at least 5 bar. The supplied com-
pressed air must be free of oil and dry.
6.2.3
Interfaces
>
Now connect all signal cables to the associated interface plugs on the
printer and secure the connector housings with the provided retainers.
6.2.4
Transport securing devices
>
Remove the transport securing device on the printer head unit.
Loosen both knurled screws and pull the transport securing device out
of the two holes on the side of the print head unit. Turn the transport
securing device around so that its rods are pointing to the right and