10.6.8 Changing the filters of the air circulation system
The air circulation system is for cleaning the air that circulates inside the
printer. The suctioned air is conveyed through two consecutive filters which,
depending on their nature, serve to separate out airborne particles or to
neutralize ozone and odors.
10.6.8.1 Changing the activated charcoal filters
The air circulation system of the ITS6 has several activated charcoal filters
(order no.:
ZEOI.000.00.Z
) which eliminates ozone and other odors from the
suctioned air.
All activated charcoal filters generally have to be replaced after 250 hours
of use. Replacement might have to be made even earlier if the printer is lo-
cated in a space where there is a proliferation of dust.
However, if a printer is operated in a clean environment or especially in
cleanrooms, the filters can be used significantly longer than the recom-
mended 250 hours and can be replaced as needed.
Fig. 111.
Activated charcoal filter
Information
Use only the original replacement part from Markem-Imaje CSAT. Oth-
erwise dirt can accumulate or odors can occur.
Replace the activated charcoal filters as follows:
>
Stop the printing process.
>
Wait until the printer has
come to a complete stop.
>
Open the safety door on the
left.