Chapter 8 Parameters
ASDA-A2R Series
8-288
Revision December, 2014
4.8sec
Result: When the output average load of the servo drive
exceeds 200% for 4.8 seconds, this DO is ON. If it exceeds
for 8 seconds, then, DO.ALRM is ON.
Setting Value: 0x11
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
WARN Warning output (Forward / reverse limit, communication
error, undervoltage, abnormal fan)
Level
triggered
ALL
Setting Value: 0x12
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
OVF
Position Command Overflows
Level
triggered
PR
Setting Value: 0x13
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
SNL
(SCWL)
Software limit (Reverse limit)
Level
triggered
ALL
Setting Value: 0x14
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
SPL
(SCCWL)
Software limit (Forward limit)
Level
triggered
ALL
Setting Value: 0x15
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
Cmd_OK Complete PR command and enter into PR mode, this DO is
ON.
When PR command is executing, this DO is OFF.
After completing the command, this DO is ON.
When the DO is ON, it means the command is completed,
but not finishing motor positioning. Please refer to DO.TPOS.
Level
triggered
PR
Setting Value: 0x16
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
CAP_OK CAP procedure completed
Level
triggered
ALL
Setting Value: 0x17
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
MC_OK When DO.Cmd_OK and TPOS are both ON, this DO is ON.
Refer to P1-48.
Level
triggered
PR
Содержание ASD-A2R-0121 Series
Страница 16: ...Table of Contents ASDA A2R Series Revision December 2014 This page is intentionally left blank...
Страница 48: ...Chapter 2 Installation ASDA A2R Series 2 18 Revision December 2014 Delta part number BR1K5W005 3 kW 10...
Страница 107: ...Chapter 3 Wiring ASDA A2R Series Revision December 2014 3 59 Connect Communication Type of Motor to CN5...
Страница 116: ...Chapter 3 Wiring ASDA A2R Series 3 68 Revision December 2014 This page is intentionally left blank...
Страница 120: ...Chapter 4 Panel Display and Operation ASDA A2R Series 4 4 Revision December 2014 Edit Setting Mode...
Страница 141: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series Revision December 2014 5 13 5 6 1 Flowchart of Tuning Procedure...
Страница 146: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 18 Revision December 2014...
Страница 152: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 24 Revision December 2014 This page is intentionally left blank...
Страница 175: ...Chapter 6 Control Mode of Operation ASDA A2R Series Revision December 2014 6 23 Frequency Domain...
Страница 180: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 28 Revision December 2014 Flowchart of Auto Resonance Suppression...
Страница 194: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 42 Revision December 2014 This page is intentionally left blank...
Страница 232: ...Chapter 7 Motion Control ASDA A2R Series 7 38 Revision December 2014 This page is intentionally left blank...
Страница 524: ...Chapter 8 Parameters ASDA A2R Series 8 292 Revision December 2014 This page is intentionally left blank...
Страница 592: ...Chapter 11 Specifications ASDA A2R Series 11 16 Revision December 2014 11 5 Force and Speed Features F S curve...
Страница 648: ...Appendix A Accessories ASDA A2R Series A 12 Revision December 2014 CN1 Quick Connector Delta Part Number ASD IF SC5020...
Страница 658: ...Appendix A Accessories ASDA A2R Series A 22 Revision December 2014 This page is intentionally left blank...