Chapter 6 Control Mode of Operation
ASDA-A2R Series
6-12
Revision December, 2014
6.2.9 Low-frequency
Vibration
Suppression in Position Mode
If the stiffness is not enough, the mechanical transmission will continue to vibrate even
when the motor stops after completing the positioning command. The function of
low-frequency vibration suppression can eliminate the vibration of mechanical
transmission. The range is between 1.0Hz and 100.0HZ. Both manual setting and auto
setting are provided.
Auto setting:
If the frequency is hard to find, it can enable the function of auto low-frequency vibration
suppression. This function automatically searches the frequency of low-frequency
vibration. If P1-29 is set to 1, the system will disable the function of low-frequency
vibration suppression automatically and starts to search the vibration frequency. When
the detected frequency remains at the same level, P1-29 will be set to 0 automatically
and set the first frequency in P1-25 and set P1-26 to 1. The second frequency will be set
in P1-27 and then set P1-28 to 1. If P1-29 is automatically set back to 0 and still has
low-frequency vibration, please check if the function of P1-26 or P1-28 is enabled. If the
value of P1-26 and P1-28 is 0, it means no frequency has been detected. Please
decrease the value of P1-30 and set P1-29 to 1 so as to search the vibration frequency
again. Please note that when the detection level is set too small, the noise will be
regarded as the low-frequency.
Содержание ASD-A2R-0121 Series
Страница 16: ...Table of Contents ASDA A2R Series Revision December 2014 This page is intentionally left blank...
Страница 48: ...Chapter 2 Installation ASDA A2R Series 2 18 Revision December 2014 Delta part number BR1K5W005 3 kW 10...
Страница 107: ...Chapter 3 Wiring ASDA A2R Series Revision December 2014 3 59 Connect Communication Type of Motor to CN5...
Страница 116: ...Chapter 3 Wiring ASDA A2R Series 3 68 Revision December 2014 This page is intentionally left blank...
Страница 120: ...Chapter 4 Panel Display and Operation ASDA A2R Series 4 4 Revision December 2014 Edit Setting Mode...
Страница 141: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series Revision December 2014 5 13 5 6 1 Flowchart of Tuning Procedure...
Страница 146: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 18 Revision December 2014...
Страница 152: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 24 Revision December 2014 This page is intentionally left blank...
Страница 175: ...Chapter 6 Control Mode of Operation ASDA A2R Series Revision December 2014 6 23 Frequency Domain...
Страница 180: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 28 Revision December 2014 Flowchart of Auto Resonance Suppression...
Страница 194: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 42 Revision December 2014 This page is intentionally left blank...
Страница 232: ...Chapter 7 Motion Control ASDA A2R Series 7 38 Revision December 2014 This page is intentionally left blank...
Страница 524: ...Chapter 8 Parameters ASDA A2R Series 8 292 Revision December 2014 This page is intentionally left blank...
Страница 592: ...Chapter 11 Specifications ASDA A2R Series 11 16 Revision December 2014 11 5 Force and Speed Features F S curve...
Страница 648: ...Appendix A Accessories ASDA A2R Series A 12 Revision December 2014 CN1 Quick Connector Delta Part Number ASD IF SC5020...
Страница 658: ...Appendix A Accessories ASDA A2R Series A 22 Revision December 2014 This page is intentionally left blank...