Chapter 10 Troubleshooting
ASDA-A2R Series
Revision December, 2014
10-13
Bad connection of the
encoder
Check if the connection between
CN2 of the drive and the encoder
of the servo motor is loose
Reconnect the wiring
The encoder is
damaged
Check if the motor is damaged
Change the motor
:
Adjustment Error
Causes
Checking Method
Corrective Actions
The analog input
contact is incorrectly
set back to zero
Measure if the voltage of the
analog input contact is the same
as the ground voltage
Correctly ground the analog
input contact
The detection device is
damaged
Reset the power supply
If the error still occurs after reset,
send the drive back to the
distributors or contact with Delta.
:
Emergency Stop
Causes
Checking Method
Corrective Actions
Press the emergency
stop button
Check if the emergency stop
button is enabled.
Activate emergency stop
:
Reverse Limit Error
Causes
Checking Method
Corrective Actions
Reverse limit switch is
activated.
Check if the limit switch is
enabled.
Enable the reverse limit switch
The servo system is
unstable.
Check the control parameter and
inertia ratio
Re-adjust the parameter or
evaluate the motor capacity.
:
Forward Limit Error
Causes
Checking Method
Corrective Actions
Forward limit switch is
activated.
Check if the limit switch is
enabled.
Enable the forward limit switch
The servo system is
unstable.
Check the control parameter and
inertia ratio
Re-adjust the parameter or
evaluate the motor capacity.
Содержание ASD-A2R-0121 Series
Страница 16: ...Table of Contents ASDA A2R Series Revision December 2014 This page is intentionally left blank...
Страница 48: ...Chapter 2 Installation ASDA A2R Series 2 18 Revision December 2014 Delta part number BR1K5W005 3 kW 10...
Страница 107: ...Chapter 3 Wiring ASDA A2R Series Revision December 2014 3 59 Connect Communication Type of Motor to CN5...
Страница 116: ...Chapter 3 Wiring ASDA A2R Series 3 68 Revision December 2014 This page is intentionally left blank...
Страница 120: ...Chapter 4 Panel Display and Operation ASDA A2R Series 4 4 Revision December 2014 Edit Setting Mode...
Страница 141: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series Revision December 2014 5 13 5 6 1 Flowchart of Tuning Procedure...
Страница 146: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 18 Revision December 2014...
Страница 152: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 24 Revision December 2014 This page is intentionally left blank...
Страница 175: ...Chapter 6 Control Mode of Operation ASDA A2R Series Revision December 2014 6 23 Frequency Domain...
Страница 180: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 28 Revision December 2014 Flowchart of Auto Resonance Suppression...
Страница 194: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 42 Revision December 2014 This page is intentionally left blank...
Страница 232: ...Chapter 7 Motion Control ASDA A2R Series 7 38 Revision December 2014 This page is intentionally left blank...
Страница 524: ...Chapter 8 Parameters ASDA A2R Series 8 292 Revision December 2014 This page is intentionally left blank...
Страница 592: ...Chapter 11 Specifications ASDA A2R Series 11 16 Revision December 2014 11 5 Force and Speed Features F S curve...
Страница 648: ...Appendix A Accessories ASDA A2R Series A 12 Revision December 2014 CN1 Quick Connector Delta Part Number ASD IF SC5020...
Страница 658: ...Appendix A Accessories ASDA A2R Series A 22 Revision December 2014 This page is intentionally left blank...