Chapter 3 Wiring
ASDA-A2R Series
Revision December, 2014
3-39
C15: Encoder OCZ output (open-collector Z pulse output)
3.3.4 The DI and DO Signal Specified by the User
If the default setting of DI/DO signal cannot satisfy the need, self-set the DI/DO signal will
do and easy. The signal function of DI1 ~ 8 and DO1 ~ 5 is determined by parameter
P2-10 ~ P2-17 and parameter P2-18 ~ P2-22 respectively. Please refer to Chapter 7.2,
which shown as the following table. Enter DI or DO code in the corresponding parameter
to setup DI/DO.
Signal Name
Pin No
Corresponding
Parameter
Signal Name
Pin No
Corresponding
Parameter
Standard
DI
DI1- CN1-9
P2-10
Standard
DO
DO1+
CN1-7
P2-18
DI2- CN1-10
P2-11
DO1-
CN1-6
DI3- CN1-34
P2-12
DO2+
CN1-5
P2-19
DI4- CN1-8
P2-13
DO2-
CN1-4
DI5- CN1-33
P2-14
DO3+
CN1-3
P2-20
DI6- CN1-32
P2-15
DO3-
CN1-2
DI7- CN1-31
P2-16
DO4+
CN1-1
P2-21
DI8- CN1-30
P2-17
DO4- CN1-26
Extension
DI
(Optional)
EDI9 CN7-2
P2-36
DO5+ CN1-28
P2-22
EDI10 CN7-3
P2-37
DO5- CN1-27
EDI11 CN7-4
P2-38
EDI12 CN7-5
P2-39
EDI13 CN7-6
P2-40
EDI14 CN7-7
P2-41
Содержание ASD-A2R-0121 Series
Страница 16: ...Table of Contents ASDA A2R Series Revision December 2014 This page is intentionally left blank...
Страница 48: ...Chapter 2 Installation ASDA A2R Series 2 18 Revision December 2014 Delta part number BR1K5W005 3 kW 10...
Страница 107: ...Chapter 3 Wiring ASDA A2R Series Revision December 2014 3 59 Connect Communication Type of Motor to CN5...
Страница 116: ...Chapter 3 Wiring ASDA A2R Series 3 68 Revision December 2014 This page is intentionally left blank...
Страница 120: ...Chapter 4 Panel Display and Operation ASDA A2R Series 4 4 Revision December 2014 Edit Setting Mode...
Страница 141: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series Revision December 2014 5 13 5 6 1 Flowchart of Tuning Procedure...
Страница 146: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 18 Revision December 2014...
Страница 152: ...Chapter 5 Trial Operation and Tuning ASDA A2R Series 5 24 Revision December 2014 This page is intentionally left blank...
Страница 175: ...Chapter 6 Control Mode of Operation ASDA A2R Series Revision December 2014 6 23 Frequency Domain...
Страница 180: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 28 Revision December 2014 Flowchart of Auto Resonance Suppression...
Страница 194: ...Chapter 6 Control Mode of Operation ASDA A2R Series 6 42 Revision December 2014 This page is intentionally left blank...
Страница 232: ...Chapter 7 Motion Control ASDA A2R Series 7 38 Revision December 2014 This page is intentionally left blank...
Страница 524: ...Chapter 8 Parameters ASDA A2R Series 8 292 Revision December 2014 This page is intentionally left blank...
Страница 592: ...Chapter 11 Specifications ASDA A2R Series 11 16 Revision December 2014 11 5 Force and Speed Features F S curve...
Страница 648: ...Appendix A Accessories ASDA A2R Series A 12 Revision December 2014 CN1 Quick Connector Delta Part Number ASD IF SC5020...
Страница 658: ...Appendix A Accessories ASDA A2R Series A 22 Revision December 2014 This page is intentionally left blank...