IMD 100 Integration manual 4189360015 Rev. G
Units conversion
Page 176 of 243
10.3.3 Converting motor temperature (T-motor, Pt100 sensor)
The temperature of the motor can be read from register
or CANopen object 2049. In the
following description, the actual temperature read, is called
Actual_temp_raw
.
The following data is needed for the conversion (Temperature is in ºC):
Table 26
Raw temperature values T-motor (Pt100)
i
Raw_value
Temperature
1
455
-60
2
1678
-50
3
2897
-40
4
4112
-30
5
4718
-25
6
5324
-20
7
6531
-10
8
7735
0
9
8935
10
10
10132
20
11
10729
25
12
11325
30
13
12514
40
14
13700
50
15
14883
60
16
16061
70
17
16650
75
18
17237
80
19
18409
90
20
19577
100
31
20741
110
32
21903
120
33
22482
125
34
23060
130
35
24214
140
36
25365
150
37
26512
160
38
27655
170
39
28225
175
40
28795
180