IMD 100 Integration manual 4189360015 Rev. G
Parameter description
Page 212 of 243
Reg ID
CAN
open
object
Parameter name
Ser. / CAN
Type
Function
Range
Unit
Factory
default
Data
type
Access
Mem/CA
N
0x1B
201B
Kern_Version /
Firmware
Status
Firmware version
N/A
N/A
N/A
U16
RO / RO
0x1C
201C
I -Kp
Configuration Current control Proportional
amplification
0 .. 100
Num
10
U16
RW / RW
0x1D
201D
I
–Ti
Configuration Current control Integration time
0 .. 10000
µs
600
U16
RW / RW
0x1E
201E
Dig_CutOff
Configuration Cutoff digital command in torque
control mode
0 .. 32767
Num
0
U16
RW / RW
0x20
2020
I -Actual
Status
Actual current value
on page
Num
N/A
I16
RO / RO
0x21
2021
I set(dig)
Set-point
Current set-point
on page
Num
0
I16
RW / RW
0x22
2022
Icmd(ramp)
Status
Current (I) command value
on page
Num
N/A
I16
RO / RO
0x23
2023
Id-ref
Status
D-current (reactive) reference
on page
Num
N/A
I16
RO / RO
0x24
2024
Imax inuse
Status
Limit of the maximum allowed
current at present time.
on page
Num
N/A
U16
RO / RO
0x25
2025
Ramp time
Configuration Ramp time for 100 % current set
point
2000 .. 32000
µs
2000
U16
RW / RW
0x26
2026
Iq -Cmd
Status
Current Command value
on page
Num
N/A
I16
RO / RO
0x27
2027
Iq actual
Status
Q-current actual
on page
Num
N/A
I16
RO / RO
0x28
2028
Id actual
Status
D-current actual
on page
Num
N/A
I16
RO / RO
0x29
2029
Vq
Status
Q-Output voltage
±4095
Num
N/A
I32
RO / RO