IMD 100 Integration manual 4189360015 Rev. G
Communication
Page 72 of 243
Table 12
RPDO3
– special commands
Used for: Executing a special command
COB ID: 0x400+Node ID
Byte 1
Byte 2
Special commands
value (Obj. 0x2003)
Example of starting pre-heating in IMD with Node ID 2:
COB
Data
Interpretation
402
02 00
Special commands (Reg. 0x03): 00 02
Table 13
RPDO4
– safety run
Used for: Initiating a safety run
COB ID: 0x500+Node ID
Byte 1
Byte 2
Fun_safety run value
(Obj. 0x2078)
Any value written in byte 1 and 2 will cause the IMD to start a safety run
(go to state 19, safety run setup)
Example of initiating safety run in IMD with Node ID 3:
COB
Data
Interpretation
503
01 00
Fun_safety run (Reg. 0x78): 00 01
Info
The IMD will always execute the last sent RPDO. If a position command is sent (RPDO1)
and a following speed command (RPDO2) are sent, the IMD will not stop at the position of
the first PDO, but will continue with the speed and direction specified in RPDO2 that was
the last sent RPDO until another RPDO is sent making it stop.