IMD 100 Integration manual 4189360015 Rev. G
Electrical HW connections and requirements
Page 38 of 243
default motor temperature sensor (see section
). When Pt 4 is not configured as
Motor temperature sensor, it can be used in the same way as the other three Pt 100 sensor inputs.
If X3 is used, the motor temperature sensors wires are connected as follows:
Terminal no.
Terminal text
Description
X3, 1
Pt 1
First terminal for Pt 1 (Pt100) temperature sensor.
NOTE If a built-in charger is used with temperature
compensation, Pt 1 terminals must be used for
the sensor.
X3, 2
Pt 1
Second terminal for Pt 1 (Pt100) temperature sensor.
NOTE If a built-in charger is used with temperature
compensation, Pt 1 terminals must be used for
the sensor.
X3, 3
Pt 2
First terminal for Pt 2 (Pt100) temperature sensor
X3, 4
Pt 2
Second terminal for Pt 2 (Pt100) temperature sensor
X3, 5
Pt 3
First terminal for Pt 3 (Pt100) temperature sensor
X3, 6
Pt 3
Second terminal for Pt 3 (Pt100) temperature sensor
X3, 7
Pt 4
First terminal for the Pt100 motor temperature sensor
X3, 8
Pt 4
Second terminal for the Pt100 motor temperature
sensor
X3, 9
KTY +
Positive terminal for the KTY 84 or PTC sensor
X3, 10
KTY -
negative terminal for the KTY 84 or PTC sensor
See wire cross section constraints in
Info
PTC sensor can be used instead of KTY sensor.