IMD 100 Integration manual 4189360015 Rev. G
IMD configuration
Page 94 of 243
The resolver in this example is an external resolver:
According to Baumer’s data sheet “P1” in the type number indicates the number of pole pairs:
1 pole pair = 2 poles.
Table 19
Motor data for configuration:
Motor data
Value
Comments
I max
160
I max = 28*5.7
≈ 160
I nom
28
Interpolation between 27.7 and 28.2
Num. of poles
4
Number of motor poles
Temperature
sensor type
KTY/PTC E3 option is a PTC thermistor, which
is very similar to
KTY 84. IMD’s KTY
input is used for this type of sensor.
Maximum
temperature
23295
Insulation class F: 40º + 105º = 145.
Extra 15º margin is added:
130º=23295 according to section
. (Data for KTY
84 conversion is used.)
N nom
1440
Nominal speed
F nom
50
Nominal frequency
V nom
230
The motor is going to be connected
as
Δ
with 230 V AC voltage
Cos Phi
0.81
Brake current
High
The brake current is calculated from
the brake consumption power:
65 W / 24 V = 2.7 A.
Brake output
ON delay
110
Break release time. The release
range is not specified, and therefore
10% delay is added.
Brake output
OFF delay
275
Break braking time. The braking
range is not specified, and therefore
10% delay is added.
Resol. poles
2
Number of resolver poles