IMD 100 Integration manual 4189360015 Rev. G
IMD configuration
Page 88 of 243
8.4.2 Configuring motor data
Configure the motor data according to the data in the motor datasheet/specifications in the
“Configuration 1/3” tab. The red dashed rectangle shows the parameters that are to be configured.
Figure 39 Motor data in IMD Manager configuration 1/3
NOTE The shown figure above shows the parameters when Asynchronous servo motor is selected as
the motor type. Not all parameters are available is other motor types are selected.
Parameters:
•
Type
: Select one of the following options in the dropdown list
o
Sync. Servo: Permanent magnet synchronous motor with feedback (resolver)
o
Async.V/F: AC induction motor, voltage frequency controlled, with no feedback
o
Async. Servo: Servo asynchronous motor with feedback (resolver)
•
I max:
Maximum motor current
– the value is given as RMS
•
I nom:
Nominal continues motor current
– the value is given in RMS
•
Num. of poles:
Number of poles in the motor (often called 2p)
•
T-sensor type:
Select whether the built-in temperature sensor is KTY 84/PTC or Pt100.