Bit
Short symbol
Description
Bit 30
OUT_ERR
0: Digital outputs driver OK.
1: Digital outputs driver overheated and all digital outputs are turned off.
Bit 31
SSI
0: no SSI connection detected, 1: SSI connection detected
13.2.10
User motor options (A4)
See also general definition of the parameter in the
Table 41
Reg. ID 0xA4, CANopen Object ID 20A4
Bit
Value
Short symbol
Function
Bit 0..4
Position
feedback
selection
1
Resolver
Feedback resolver
12
sensorless
Control without feedback sensor
Bit 5..15
Reserved
13.2.11
Logic in/out block state (D8)
See also general definition of the parameter in the
Table 42
Reg. ID 0xD8, CANopen Object ID 20D8
Bit
Name
Description
Bit 0
Limit 1
0: Digital input limit 1 inactive, 1: Digital input limit 1 active
Bit 1
Limit 2
0: Digital input limit 2 inactive, 1: Digital input limit 2 active
Bit 2
Din 2
Result of Din2 logic: 0: Din2 false, 1: Din 2 true
Bit 3
Din 1
Result of Din1 logic: 0: Din1 false, 1: Din 1 true
Bit 4
RUN
0: Hardware enable inactive, 1: Hardware enable active
Bit 5
RFE
0: motor drive disabled, 1: motor drive enabled
Bit 6
Not used
Bit 7
Not used
Bit 8
Dout 1
0: Digital output Dout 1 inactive, 1: Digital output Dout 1 active
Bit 9
Dout 2
0: Digital output Dout 2 inactive, 1: Digital output Dout 2 active
Bit 10
SCR 1 and 2
0: Hardware relay output SCR inactive, 1: Hardware relay output SCR
active
Bit 11
GO
0: Internal enable GO inactive, 1: Internal enable GO active
Bit 12
Dout 3
0: Digital output Dout 3 inactive, 1: Digital output Dout 3 active
Info
Use only the listed values.