Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[6-0E]
R/W
E-07 = 0
40~ 60°C, step: 1°C
60°C
E-07 = 3
40~ 75°C, step: 1°C
75°C
E-07 = 5
40~ 80°C, step: 1°C
80°C
E-07 = 7
40~ 60°C, step: 1°C
60°C
E-07 = 8
40~ 75°C, step: 1°C
75°C
9.I
[7-00]
R/W
0~4°C, step: 1°C
0°C
9.I
[7-01]
R/W
2~40°C, step: 1°C
2°C
9.I
[7-02]
R/W
0: Single zone
1: Dual zone
9.I
[7-03]
2.5
9.I
[7-04]
0
9.I
[7-05]
R/W
0: Very high
1: High
2: Medium
3: Low
4: Very low
9.I
[7-06]
R/W
0: Disabled
1: Enabled
9.I
[7-07]
R/W
0: No
1: Yes
9.I
[7-09]
R/W
20%
9.I
[7-0A]
R/W
20~95%, step 5%
95%
9.I
[7-0B]
R/W
20~95%, step 5%
95%
9.I
[7-0C]
R/W
20~300 seconds, step 5 sec
125 seconds
9.I
[8-00]
R/W
0~20 min, step 1 min
1 min
9.I
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.I
[8-02]
R/W
0~10 hour, step: 0,5 hour
3 hour
9.I
[8-03]
R/W
20~95 min, step: 5 min
50 min
9.I
[8-04]
R/W
0~95 min, step: 5 min
95 min
9.I
[8-05]
R/W
0: No
1: Yes
9.I
[8-06]
R/W
0~10°C, step: 1°C
5°C
9.I
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
9.I
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
9.I
[8-09]
R/W
[9-01]~[9-00], step: 1°C
35°C
9.I
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
33°C
9.I
[8-0B]
13
9.I
[8-0C]
10
9.I
[8-0D]
16
9.I
[9-00]
R/W ([2-
0C]
≠
2)
R/O ([2-
0C] = 2)
[2-0C]=2:
37~70, step: 1°C
65°C
[2-0C]
≠
2:
37~55, step: 1°C
55°C
9.I
[9-01]
R/W
15~37°C, step: 1°C
25°C
9.I
[9-02]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-03]
R/W
5~18°C, step: 1°C
5°C
9.I
[9-04]
R/W
1~4°C, step: 1°C
1°C
9.I
[9-05]
R/W
15~37°C, step: 1°C
25°C
9.I
[9-06]
R/W ([2-
0C]
≠
2)
R/O ([2-
0C] = 2)
[2-0C]=2:
37~70, step: 1°C
65°C
[2-0C]
≠
2:
37~55, step: 1°C
55°C
9.I
[9-07]
R/W
5~18°C, step: 1°C
7°C
9.I
[9-08]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-09]
R/W
1~18°C, step: 1°C
18°C
9.I
[9-0A]
R/W
[3-07]
~
[3-06]°C, step: 0,5°C
23°C
9.I
[9-0B]
R/W
[3-09]
~
[3-08]°C, step: 0,5°C
23°C
Booster heater delay timer.
Additional running time for the maximum running time.
Domestic hot water booster heater hysteresis.
How many leaving water temperature zones are there?
--
--
Boiler efficiency
HP forced OFF
BBR16 activation*
*BBR16 settings are only visible when the language of the user
interface is set to Swedish.
Minimum running time for domestic hot water operation.
Additional zone fixed pump PWM, in case a bizone kit is installed.
Main zone fixed pump PWM, in case a bizone kit is installed.
Time needed by the mixing valve to turn from one side to the
other, in case a bizone kit is installed.
What is the maximum temperature setpoint?
Domestic hot water booster heater overshoot temperature.
What is the desired eco main LWT in cooling?
What is the desired eco main LWT in heating?
--
--
Maximum running time for domestic hot water operation.
What is the mimimum desired LWT for add. zone in heating?
What is the desired comfort main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the mimimum desired LWT for main zone in heating?
Anti-recycling time.
What is the allowed LWT undershoot during cooling start-up?
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
--
What is the maximum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
What is the room buffering temperature in heating?
What is the room buffering temperature in Cooling?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
How much is the minimum pump PWM value.