7
|
Technical data
Service manual
282
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
English
Translation
M1C
Compressor motor
M1F
Fan motor
MR*
Magnetic relay
N
Connector
PCB1
Printed circuit board (main)
PS
Switching power supply
Q1L
Thermal protector
Q1DI
#
Earth leakage circuit breaker
Q*
Insulated gate bipolar transistor (IGBT)
R1T
Thermistor (air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (discharge)
RTH2
Resistor
S
Connector
S1PH
High pressure switch
S2~80
Connector
SA1
Surge arrestor
SHM
Terminal strip fixed plate
U, V, W
Connector
V3, V4, V401
Varistor
X*A
Connector
X*M
Terminal strip
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4-way valve)
Z*C
Noise filter (ferrite core)
Z*F
Noise filter
NOTES:
1
When operating, do not short-circuit protection device(s) S1PH and Q1L.
2
Colours: BLK: black; RED: red; BLU: blue; WHT: white; GRN: green; YLW:
yellow
Hydro module
The wiring diagram is delivered with the unit, located at the inside of the service
cover.
Translation of text on wiring diagram:
English
Translation
(1) Connection diagram
(1) Connection diagram
Hydro
Hydro module
Outdoor
Outdoor
draft – 31/05/2022 15:53