4
|
Components
Service manual
180
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
281].
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
Is the problem solved?
Action
Yes
No further actions required.
No
and continue with the next procedure.
To remove a fuse of the hydro PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
202].
2
Remove the fuse from the PCB.
a
a
Fuse
3
To install a fuse on the hydro PCB, see
178].
To install a fuse on the hydro PCB
WARNING
For continued protection against risk of fire, replace ONLY with same type and rating
of fuse.
1
Install the fuse on the correct location on the PCB.
CAUTION
Make sure the fuse is plugged‑in correctly (contact with the fuse holder).
draft – 31/05/2022 15:53