4
|
Components
Service manual
208
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
4.16.9 To install the switch box
1
Install the switch box on the correct location in the unit.
2
Connect the ground wire to the switch box and tighten the screw.
3
Connect the wiring to the switch box.
a
b
a
Wiring
b
Ground wire
4
Connect the compressor harness connector.
a
b c
c
d
e
f
g
a
Drip proof cover
b
Cable clamp expansion valve harness
c
Cable clamp thermistor harness
d
Cable clamp 4‑way valve harness
e
Fan motor assembly harness
f
Main PCB
g
Compressor harness connector
5
Connect the connectors to the main PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.