4/14
Breadcrumb
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
4.7
[9-0D]
R/W
0~8, step:1
0 : No limitation
1~4 : 90~60% pump speed
5~8 : 90~60% pump speed during
sampling
6 80% pump speed
Space heating / cooling
4.9
[F-00]
R/W
0: Restricted
1: Allowed
4.A
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
4.B
[9-04]
R/W
1~4°C, step: 1°C
1°C
4.C
[2-06]
R/W
0: No
1: Yes
Tank
5.2
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
5.3
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
5.4
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
5.6
[6-0D]
R/W
0: Reheat only
1: Sc reheat
2: Schedule only
└─
Disinfection
5.7.1
[2-01]
R/W
0: No
1: Yes
5.7.2
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
5.7.3
[2-02]
R/W
0~23 hour, step: 1 hour
1
5.7.4
[2-03]
R/W
60°C
60°C
5.7.5
[2-04]
R/W
40~60 min, step: 5 min
10 min
Tank
5.8
[6-0E]
R/W
E-07 = 0
40~ 60°C, step: 1°C
60°C
E-07 = 3
40~ 75°C, step: 1°C
75°C
E-07 = 5
40~ 80°C, step: 1°C
80°C
E-07 = 7
40~ 60°C, step: 1°C
60°C
E-07 = 8
40~ 75°C, step: 1°C
75°C
5.9
[6-00]
R/W
2~40°C, step: 1°C
8°C
5.A
[6-08]
R/W
2~20°C, step: 1°C
10°C
5.B
R/W
0: Fixed
1: Weather dependent
└─
WD curve
5.C
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
55°C
5.C
[0-0C]
R/W
Min(45~[6-0E])
~
[6-0E]°C, step: 1°C
60°C
5.C
[0-0D]
R/W
10~25°C, step: 1°C
15°C
5.C
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
Tank
5.D
[6-01]
R/W
0~10°C, step: 1°C
2°C
5.E
R/O
0: 2-points
1: Slope-Offset
User settings
└─
Quiet
7.4.1
R/W
0: OFF
1: Manual
2: Automatic
7.4.3
R/W
0: Quiet
1: More Quiet
2: Most Quiet
└─
Electricity price
7.5.1
R/W
0,00~990/kWh
1/kWh
7.5.2
R/W
0,00~990/kWh
1/kWh
7.5.3
R/W
0,00~990/kWh
1/kWh
User settings
7.6
R/W
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Pump speed limitation
Pump outside range
Increase around 0°C
Overshoot
Antifrost
Comfort setpoint
Eco setpoint
Reheat setpoint
Heat up mode
Activation
Operation day
Start time
Tank setpoint
Duration
Maximum
Hysteresis
Reheat hysteresis
Setpoint mode
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Margin
WD curve type
Mode
Level
High
Medium
Low
Gas price
4P685235-1 - 2022.03
(*1) EBLA*_(*2) EDLA*_(*3) *23V3_(*4) *2V3