Software
Crestron
D3 Pro
™
With touchpanels, various connection types are possible. If the panel project
should be uploaded over Cresnet (via the control system), you want to
specify the connection type and address (if over TCP/IP) of the control
system.
If the touchpanel should be uploaded directly over TCP/IP, the select
TCP/IP
as the connection type and enter the IP address of the touchpanel
(NOT the control system). You must also select the
Send directly to
touchpanel
checkbox.
If the touchpanel should be uploaded directly over RS-232, select
Serial
as
the connection type and click
Send directly to touchpanel
.
To communicate directly to an Ethernet touchpanel, select
TCP/IP
as the
connection type, enter the IP address of the panel (not the control system)
and select
Send directly to touchpanel
.
3. Click
Upload
to begin the file transfer. If the control processor already has a
program installed in memory, you will be prompted to save that program to
disc. To save the program, click
Yes
and
browse to the directory where you
want to save the SPZ file.
4. As files are transferred, first to the control processor and then to touchpanels,
D3 Pro will display a progress bar.
In applications that do not include wireless panels, D3 Pro will display the
progress bar as it uploads each project to every selected touchpanel. In
applications that do include wireless panels, D3 Pro will interrupt the upload
94
•
Crestron D3 Pro™
Reference Guide – DOC. 5998a