4
4
4-38
4-38
Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Cassette Pickup Roller (250)
Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Cassette Pickup Roller (250)
Removing the Fixing Unit
1) Open the right cover
2) Remove the fixing unit.
- 2 screws
x2
MEMO:
Hold the fixing unit at the position shown below.
F-4-85
F-4-85
F-4-84
F-4-84
Removing the Cassette Pickup Roller (250-sheet 1st
Cassette Model)
1) Remove the cassette from the main unit.
2) Open the right cover.
3) Release the claws and slide the rear bearing.
4) Remove the cassette pickup roller.
x1
爪
MEMO:
Reassemble the parts as shown below.
F-4-87
F-4-87
F-4-86
F-4-86
Содержание IMAGERUNNER 2530
Страница 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER 2530 2525 2520 Series Service Manual...
Страница 4: ...Blank Page...
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Страница 111: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Страница 159: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Страница 166: ...6 6 Troubleshooting Troubleshooting Upgrading Targets and Procedure...
Страница 171: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code...
Страница 186: ...8 8 Service Mode Service Mode Outline Details of Service Mode...
Страница 321: ...Service Tools General Circuit Diagram Appendix...