GM2 Series VFD
Perform Basic Operations
890054-00-00
Navigating Directly to Different Codes (Jump Codes)
The following examples detail navigating to code dr. 95, from the initial code in the Drive group (dr.
0). Using the arrow keys, pressing [UP] will loop backwards from dr.0 to dr.95. The table shows how
to program in the parameter number and jump directly to it. These examples apply to all groups
whenever you need to navigate to a specific parameter code number.
Using arrow keys:
Using Jump Code:
Step
Instruction
Keypad Display
1
Ensure that you are currently at the first code of the Drive
group (dr.0).
2
Press the [ENT] key.
Number "9" will flash.
3
Press the [
▼
] key and change the ones' place number to
"5", so the destination code is "5".
4
Press the [MODE] to move to the tens' place.
The cursor will move to the left and "05" will be displayed.
At this time, the number "0" will be flashing.
5
Press the [
▲
] key to change the tens' place number to "9",
so the destination code is "95".
6
Press the [ENT] key.
Code dr.95 is displayed.
9
5
0
5
9
5
dr.95
dr.0
Содержание RSi GM2 Series
Страница 2: ...ii...
Страница 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Страница 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Страница 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Страница 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...