Table of Functions
228
GM2 Series VFD
890054-00-00
Code
Comm.
Address
Name
Setting Range
Initial Value
Property*
V/F
SL
Ref.
CM.35
0h1723
Output
communication
address 5
0000
–FFFF Hex
0
O
O
O
CM.36
0h1724
Output
communication
address 6
0000
–FFFF Hex
0
O
O
O
CM.37
0h1725
Output
communication
address 7
0000
–FFFF Hex
0
O
O
O
CM.38
0h1726
Output
communication
address 8
0000
–FFFF Hex
0
O
O
O
CM.50
0h1732
Number of
input
parameters
0
–8
2
O
O
O
CM.51
0h1733
Input
communication
address 1
0000
–FFFF Hex
5
X
O
O
CM.52
0h1734
Input
communication
address 2
0000
–FFFF Hex
6
X
O
O
CM.53
0h1735
Input
communication
address 3
0000
–FFFF Hex
0
X
O
O
CM.54
0h1736
Input
communication
address 4
0000
–FFFF Hex
0
X
O
O
CM.55
0h1737
Input
communication
address 5
0000
–FFFF Hex
0
X
O
O
CM.56
0h1738
Input
communication
address 6
0000
–FFFF Hex
0
X
O
O
CM.57
0h1739
Input
communication
address 7
0000
–FFFF Hex
0
X
O
O
CM.58
0h173A
Input
communication
address 8
0000
–FFFF Hex
0
X
O
O
CM.68
0h1744
Field bus data
swap
0
No
0
X
O
O
-
1
Yes
CM.70
0h1746
Communication
multi-function
(digital) input 1
0
None
0: None
O
O
O
CM.71
0h1747
Communication
multi-function
(digital) input 2
1
Fx
0: None
O
O
O
CM.72
0h1748
Communication
multi-function
(digital) input 3
2
Rx
0: None
O
O
O
Содержание RSi GM2 Series
Страница 2: ...ii...
Страница 58: ...48 GM2 Series VFD Perform Basic Operations 890054 00 00...
Страница 122: ...Learning Advanced Features 112 890054 00 00 GM2 Series VFD PID control block diagram...
Страница 188: ...Learning Protection Features 178 GM2 Series VFD 890054 00 00...
Страница 279: ...Technical Specification 269 890054 00 00 GM2 Series VFD...