Performance Monitoring and Alarms
136
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.44
SONET Path STS AIS Alarm
This alarm applies only to Mediant 3000 TP-6310.
SONET Path STS AIS Alarm
Description
This alarm is issued when the AIS condition is present on the SONET
Path #m.
SNMP Alarm
acSonetPathSTSAISAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.62
Alarm Title
SONET Path STS AIS Alarm
Alarm Source
Interfaces#0/Path#<m>
Alarm Type
communicationsAlarm
Probable Cause
receiveFailure
Severity
Critical / clear
Additional Info
Corrective Action
Check the following and correct according to the appropriate reason:
There is higher level failure: LOS, LOF, AIS-L
A Path Trace Identifier mismatch occurred
•
Path is unequipped on the Far-End
Содержание Mediant 3000 TP-6310
Страница 2: ......
Страница 10: ......
Страница 11: ...Version 7 0 11 OAM Guide Performance Monitoring and Alarms 1 Introduction This page is intentionally left blank...
Страница 12: ......
Страница 116: ...Performance Monitoring and Alarms 116 Document LTRT 32111 Mediant 3000 with TP 6310 Cleared HA system is active...