Performance Monitoring and Alarms
80
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.2.7
Hardware Replaced
Hardware Replaced
Textual Description
Originated when the EMS discovers a different gateway (according to
the MAC address) to what was initially defined, while the Hardware
Type remains the same.
Hardware Replace is discovered by the MAC address and performed
during Board Started trap.
SNMP OID
acEMSHardwareReplaceAlarm - 1.3.6.1.4.1.5003.9.20.3.2.0.15
AlarmTitle
[Event] Hardware Replaced
ItuAlarmType
Equipment Alarm
AlarmSource
Media Gateway
Probable Cause
Other
Severity
Major
Additional Info
-
Corrective Action
-
Media Gateways
MediaPacks, Mediant 1000, Mediant 2000, Mediant 3000
3.2.8
HTTP/HTTPS Access Disabled
HTTP/HTTPS Access Disabled
Textual Description
Originated when HTTP access is disabled by EMS hardening but the
EMS manages media gateways that require HTTP access for software
upgrade.
Originated on server startup.
SNMP OID
acEMSHTTPDisabled - 1.3.6.1.4.1.5003.9.20.3.2.0.16
AlarmTitle
[Event] HTTP/HTTPS Access Disabled
ItuAlarmType
Environmental Alarm
AlarmSource
EMS Server
Probable Cause
Application Subsystem Failure
Severity
Major
Additional Info
-
Corrective Action
Separate the gateways between two EMS Servers (secured &
unsecured)
Media Gateways
Gateways using the HTTP server for the software upgrade procedure:
MediaPacks, Mediant 1000, Mediant 2000, Mediant 3000