Performance Monitoring and Alarms
28
Document #: LTRT-32111
Mediant 3000 with TP-6310
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Tel to IP Fax Call
Attempts
HIST
Counter Indicates the number of attempted fax calls for Tel to IP
direction, during last interval.
Mib name: acPMSIPFaxAttemptedCallsValTel2IP
Tel to IP Successful Fax
Calls
HIST
Counter Indicates the number of successful fax calls for Tel to
IP direction, during last interval.
Mib name: acPMSIPFaxSuccessCallsValTel2IP
Tel to IP Average Call
Duration [sec]
HIST
Gauge Indicates the average call duration of established calls
for Tel to IP direction, during last interval.
Mib name: acPMSIPCallDurationAverageTel2IP
2.4.8
Tab: Trunk Statistics
Frame: Gateway System Monitoring (Configuration), Tab: Trunk Statistics
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Trunk utilization Avg
HIST
Gauge Indicates the Average of simultaneously busy DS0
channels on this Trunk up to this point in time during
the collection interval, as indicated by the Time Interval.
A busy channel is when the Physical DS0 Termination
isn't in Null context or OOS. A Trunk is either E1 or T1.
Mib name: acPMTrunkUtilizationAverage
Trunk utilization Min
HIST
Gauge Indicates the Minimum of simultaneously busy DS0
channels on this Trunk up to this point in time during
the collection interval, as indicated by the Time Interval.
A busy channel is when the Physical DS0 Termination
isn't in Null context or OOS. A Trunk is either E1 or T1.
Mib name: acPMTrunkUtilizationMin
Trunk utilization Max
HIST
Gauge Indicates the Maximum of simultaneously busy DS0
channels on this Trunk up to this point in time during
the collection interval, as indicated by the Time Interval.
A busy channel is when the Physical DS0 Termination
isn't in Null context or OOS. A Trunk is either E1 or T1.
Mib name: acPMTrunkUtilizationMax
Trunk Errored Seconds
HIST
Gauge Indicates the number of Errored Seconds.
Mib name: dsx1IntervalESs
Trunk Controlled Slip
Seconds
HIST
Gauge Indicates the number of Controlled Slip Seconds.
Mib name: dsx1IntervalCSSs
Trunk Path Coding
Violations
HIST
Gauge Indicates the number of Path Coding Violations.
Mib name: dsx1IntervalPCVs
Trunk Bursty Errored
Seconds
HIST
Gauge Indicates the number of Bursty Errored Seconds.
Mib name: dsx1IntervalBESs