Performance Monitoring and Alarms
130
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.37
Trunk RAI Alarm
This alarm to E1/T1Trunks.
Trunk RAI Alarm
Description
This alarm indicates a loss of frame at the trunk's far end.
SNMP Alarm
acTrunksAlarmFarEndLOF
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.52
Alarm Title
Trunk RAI Alarm
Alarm Source
Port#<n> where n is the digital trunk number
Alarm Type
communicationsAlarm
Probable Cause
transmitFailure
Severity
Critical
Additional Info
Corrective Action
Check trunk's connectivity