Version 7.0
103
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.10
Ethernet Link Down Alarm
Ethernet Link Down Alarm
Description
This alarm indicates that the Ethernet link is down or remote Ethernet
link is down and the board has no communication to any other host.
No link at all.
Link is up again.
Primary link is down only - 'Primary Link is lost. Switching to
Secondary Link''
SNMP Alarm
acBoardEthernetLinkAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Alarm Title
Ethernet Link Down Alarm
Alarm Type
Equipment Alarm
Alarm Source
Probable Cause
Input/Output Device Error
Other
Underlying resource unavailable
Severity
Critical
Cleared
Major
Additional Info1,2,3
-
Corrective Action
Ensure that both Ethernet cables are plugged into the back of the
system. Inspect the system's Ethernet link lights to determine which
interface is failing. Reconnect the cable or fix the network problem.