Version 7.0
31
Performance Monitoring and Alarms
Performance Monitoring and Alarms
2. Performance Monitoring Parameters
2.5
Frame: Gateway System Monitoring (History)
2.5.1
Tab: System IP
Frame: Gateway System Monitoring (History), Tab: System IP
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Number of Outgoing
KBytes
HIST
Counter Counts the total number of outgoing Kbytes (1000
bytes) from the interface during the last interval.
Mib name: acPMNetUtilKBytesVolumeTx
Number of Incoming
KBytes
HIST
Counter Counts the total number of Kbytes (1000 bytes)
received on the interface, including those received in
error, during the last interval.
Mib name: acPMNetUtilKBytesVolumeRx
Number of Outgoing Pkts HIST
Counter Counts the total number of outgoing Packets from the
interface during the last interval.
Mib name: acPMNetUtilPacketsVolumeTx
Number of Incoming Pkts HIST
Counter Counts the total number of Packets received on the
interface, including those received in error, during the
last interval.
Mib name: acPMNetUtilPacketsVolumeRx
Number of Incoming
Discarded Pkts
HIST
Counter Counts the total number of malformed IP Packets
received on the interface during the last interval. These
are packets which are corrupted or discarded due to
errors in their IP headers, including bad checksums,
version number mismatch, other format errors, time-to-
live exceeded, errors discovered in processing their IP
options, etc.
Mib name: acPMNetUtilDiscardedPacketsVal
2.5.2
Tab: VoP Call Statistics
Frame: Gateway System Monitoring (History), Tab: VoP Call Statistics
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Num of Active Contexts
Avg
HIST
Gauge Indicates the average number of voice calls connected
on the gateway since the last clear.
Mib name: acPMActiveContextCountAverage
Num of Active Contexts
Min
HIST
Gauge Indicates the minimum number of voice calls connected
on the gateway since the last clear.
Mib name: acPMActiveContextCountMin