Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.2.11
Cold Start Missed
Cold Start Missed
Textual Description
Originated when Carrier Grade Alarm System recognizes coldStart
trap has been missed.
SNMP OID
acEMSNodeColdStartMissedEvent - 1.3.6.1.4.1.5003.9.20.3.2.0.20
AlarmTitle
[Event] Cold Start Missed
ItuAlarmType
Other
AlarmSource
Probable Cause
Receive failure
Severity
Clear
Additional Info
Corrective Action
Media Gateways
All the managed Gateways
3.2.12
Security Alarm
Security Alarm
Textual Description
Activated when one of more Radius servers are not reachable. When
none of the radius servers can be reached, a Critical Severity alarm is
generated.
SNMP OID
acEMSSecurityAlarm - 1.3.6.1.4.1.5003.9.20.3.2.0.23
AlarmTitle
Security Alarm
ItuAlarmType
Processing Error Alarm
AlarmSource
EMS Server / Radius <#>
Probable Cause
Other
Severity
Minor, Major, Critical
Additional Info
Corrective Action
Media Gateways