Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.30
SONET Line RDI Alarm
This alarm applies only to the Mediant 3000.
SONET Line RDI Alarm
Description
This alarm indicates that RDI condition is present on SONET-Line
no#m.
The field 'sonetLineCurrentStatus' in the sonetLineCurrentTable will
have a value of sonetLineRDI (4).
SNMP Alarm
acSonetLineRDIAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.41
Alarm Source
Interfaces#0/Sonet#<m>, where
m
is the SONET interface number
Event Type
communicationsAlarm
Probable Cause
transmitFailure
Alarm Severity
Condition
<text>
Corrective Action
Critical (default)
RDI condition is
present on SONET-
Line #n
SONET-Line RDI
1.
Check the
remote site
for alarm conditions.
2.
Correct a line problem
that has arisen from the
remote interface
.
Note that the
'sonetLineCurrentStatus'
field in the
sonetLineCurrentTable will
have a value
sonetLineRDI (4)
Cleared
RDI condition is not
present.
-
-