Performance Monitoring and Alarms
118
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.4.24
HA System Switch Over Alarm
HA System Switch Over Alarm
Description
Sent when a switchover from the active to the redundant module has
occurred.
SNMP Alarm
acHASystemSwitchOverAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.35
Default Severity
Critical
Alarm Source
System#0/Module#<m>, where
m
is the blade module’s slot number
Event Type
qualityOfServiceAlarm
Probable Cause
outOfService
Alarm Severity
Condition
<text>
Corrective Action
Critical (default)
A switchover
from the
active to the
redundant
unit has
occurred
Switch-over: See the
acHASystemFaultAlarm
table above
See Section 3.4.23 for details.
Cleared
10 seconds
have passed
since the
switchover
-
-