Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.23
HA System Configuration Mismatch Alarm
This alarm applies only to the Mediant 3000.
HA System Configuration Mismatch Alarm
Description
HA feature is active. The active module was unable to transfer the
License Key to the redundant module.
SNMP Alarm
acHASystemConfigMismatchAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.34
Alarm Source
System#0/Module#<m>, where
m
is the blade module’s slot number
Alarm Type
processingErrorAlarm
Probable Cause
configurationOrCustomizationError
Alarm Severity
Condition
<text>
Corrective Action
Major (default)
HA feature
is active:
Configuration mismatch in the
system:
The actions for the
conditions are described
below.
License
Keys of
Active and
Redundant
modules
are
different.
Active and Redundant
modules have different
feature keys.
Update the Feature Keys of
the Active and Redundant
modules.
The Active
module
was
unable to
pass on to
the
Redundant
module
the
License
Key.
Fail to update the redundant
with feature key.
Replace the Feature Key of
the Redundant module – it
may be invalid.
License
key of the
Redundant
module is
invalid.
Feature key did not update in
redundant module.
Replace the Feature Key of
the Redundant module – it
may be invalid.
Cleared
Successful
License
Key
update
The feature key was
successfully updated in the
redundant module
-