Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
HW fault. TER has old
version or is not
functional
(applicable only to
Mediant 3000)
Replace the TER card.
HW fault. invalid TER
Type
(applicable only to
Mediant 3000)
Replace the TER card.
HW fault. invalid TER
active/redundant state
(applicable only to
Mediant 3000)
Replace the TER card.
HW fault. Error reading
GbE state
(applicable only to
Mediant 3000)
Replace the TER card.
Redundant module is
missing
(applicable only to
Mediant 3000)
1.
Insert the redundant module
into the system.
2.
If the error continues, reset /
replace the module.
Redundant is not
connecting
(applicable only to
Mediant 3000)
Reset / replace the redundant
module.
Redundant is not
reconnecting after
deliberate restart
Reset / replace the redundant
module.
No Ethernet Link in
redundant module
Connect Ethernet links to the
redundant module
SA module faulty or
missing
(applicable only to
Mediant 3000)
Make sure the Shelf Alarm
module is inserted correctly.
Eth link error
HA was lost due to switchover,
Connect the Eth link back.
Higher HA priority
(Not applicable to
Mediant 3000)
HA was lost due to switchover
to unit with higher HA priority
and should return automatically
after a few minutes.
Corrective action is not
required.
Network watchdog
error
HA was lost due to switchover ,
Fix the network connectivity
from failed unit
Minor
HA feature is
active and the
redundant
module is in
startup mode
and hasn’t
connected yet
Waiting for redundant
to connect
(applicable only to
Mediant 3000)
Corrective action is not
required.