GW110X series 

Modbus Gateway User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 1.0.1, Nov 2015 

Shenzhen 3onedata Technology Co., Ltd 

www.3onedata.com 

Содержание GW110X Series

Страница 1: ...Shenzhen 3onedata Technology Co Ltd GW110X series Modbus Gateway User Manual Version 1 0 1 Nov 2015 Shenzhen 3onedata Technology Co Ltd www 3onedata com...

Страница 2: ...elong to their respective manufacturers Agreement As the product version upgrades or other reasons this document is subject to change without notice Unless other agreement this document only as a guid...

Страница 3: ...lation 8 3 2 Appearance and Dimension 10 Chapter 4 Packing List 13 Chapter 5 Telnet Management Function 14 5 1 Configuration through Telnet 14 5 2 How to modify the PC s IP address 15 Chapter 6 WEB Ma...

Страница 4: ...ogy Co Ltd 3 www 3onedata com 6 8 1 System information 37 6 8 2 System file 38 6 8 3 Logout Reboot 39 Chapter 7 Repair and Service 40 7 1 Internet Service 40 7 2 Make a call to our technical office 40...

Страница 5: ...arantee the application of the entire real environment The series of products using EMC protection design Power has over current over voltage protection and can work in rugged environment The design s...

Страница 6: ...s the information received and decides what action to take and extracts all data or other information contained in the information If you need to reply the controller will write the reply message and...

Страница 7: ...Shenzhen 3onedata Technology Co Ltd 3 www 3onedata com The basic system framework is as follows Modbus basic framework Figure 2 1 1 Modbus basic framework Figure 2 1 2...

Страница 8: ...n each ASCII character contains 2 hexadecimal characters The information in each ASCII character contains 1 hexadecimal characters Each byte 1 start bit 1 start bit 8 data bits 7 8 data bits 1 parity...

Страница 9: ...n GW110X series front panel Pin definition of the RJ45 port as shown in the following figure Connect by UTP or STP The connect distance is not more than 100m 100Mbps is used 120 of UTP 10Mbps is used...

Страница 10: ...ce through straight through cable or cross over cable directly Serial port connection GW1101 series RS 485 422 port provides 5 bit industrial terminal block The PIN defines is as follows PIN RS 485 PI...

Страница 11: ...statues LED Indicator Description PWR ON Power is connected Function natural OFF Power is disconnected or function nu natural RUN Flashing System Running steadily OFF System did not run or running un...

Страница 12: ...en give the device to power up continue for about 5 seconds to restore the factory settings 3 1 5 Device installation Before installation confirm that the work environment meet the installation requir...

Страница 13: ...les should be straight in the hallways and turning 6 Cable should be straight in the groove and cannot beyond the groove in case of holding back the inlet and outlet holes Cables should be banded and...

Страница 14: ...2 Appearance and Dimension Appearance GW1101 1D RS 232 P 9 48VDC GW1101 1D RS 485 P 9 48VDC GW1102 2D RS 232 P 9 48VDC GW1102 2D RS 485 P 9 48VDC GW1104 4DI RS 485 P 9 48VDC GW1104 4D RS 232 P 9 48VD...

Страница 15: ...Shenzhen 3onedata Technology Co Ltd 11 www 3onedata com Dimension Unit mm GW1101 series RS 232 RS 485 422 GW1102 series RS 232 RS 485 422...

Страница 16: ...Ltd 12 www 3onedata com GW1104 series product structure size Length Width High is the same only the interfaces are not the same GW1108 series product structure size Length Width High is the same only...

Страница 17: ...hapter 4 Packing List The first time use this product please check the packaging is intact or not and the attachment is complete or not at first Item Quality MODBUS Gateway Device 1pcs User manual 1pc...

Страница 18: ...agement view 2 If PC and GW110X in the same local area network the IP address must in a same network segment otherwise PC and GW110X must cross router If satisfied these two requirements can use telne...

Страница 19: ...me network segment otherwise PC and GW110X must cross router When modify PC s address please make sure PC and GW110X series in a same local area network please reference the operation step as follows...

Страница 20: ...n 4 Install and start TCP IP protocol 2 Establish correct network configuration GW110X series default IP address 192 168 1 254 subnet mask 255 255 255 0 if configure in local area please make sure IP...

Страница 21: ...k Gateway DNS Server and IP Report Address setting Security setting Device Security Web Console Telnet Console Device Search Firmware Upgrade IP Filtering IP address filtering Mac Filtering MAC addres...

Страница 22: ...y place Contact information The contact information of person when maintenance the device it can be configured in system information MAC address Hardware address 48bits 6 bytes 16 hexadecimal it is un...

Страница 23: ...work mode Baud rate bps 300 115200 10pcs band rate optional Baud rate choice Parity None Even Odd Mark Space Checkout choice Data bits bits 5 6 7 8 The parameter of serial Stop bits bits 1 2 The last...

Страница 24: ...d 2 bit Flow Control Flow control is determined by product hardware For some reason cannot communicate communication is blocked can open the flow control to ease Flow control allows the data receiving...

Страница 25: ...ts stop bits parity bit flow control FIFO and so on As shown below Figure 6 3 2 6 4 Modbus Setting 6 4 1 Modbus parameter setting Modbus parameter configuration menu Configuration menu Data option Des...

Страница 26: ...in the Modbus monitor software and the is not done at present regardless of whether the parameter is enabled the default gateway sends a TCP Modbus exception to the Modbus monitoring software Response...

Страница 27: ...The Modbus protocol provides that all of the slave device must have a unique ID number 1 247 The ID number is used to identify the address from the slave device to respond to requests from the master...

Страница 28: ...Web interface for the product click Modbus settings slave ID Configuration Web interface as shown below Figure 6 4 2 Slave configuration menu Data option Description Channel Type RTU Master RTU Slave...

Страница 29: ...gure 6 4 3 Enter the WEB configuration interface slave ID set the channel NO 1 the working mode is RTU Master Click Add the pop up window setting parameters as shown below Figure 6 4 4 Set to complete...

Страница 30: ...ation mode of the gateway is set to ASCII Slave Figure 6 4 5 Enter the WEB configuration interface slave ID set the channel NO 1 the working mode is ASCII slave Click Modify the pop up window setting...

Страница 31: ...cation the operation mode of the gateway is set to RTU slave Figure 6 4 8 Related settings can refer to the ASCII Slave mode 4 ASCII Master mode When the users will Modbus ASCII master device and Modb...

Страница 32: ...customer service We do our best for your service Use TCP Master instead of serial Master Modify Slave ID In this case the customer s old control system contains multiple subsystems that are based on t...

Страница 33: ...to the monitoring management Slave devices Two different Master to the same time to access the Slave equipment how to do Multi port Modbus gateway is very suitable for this kind of situation directly...

Страница 34: ...ipment the instrument the manufacturing machine and the PLC controller To integrate these devices into the network it takes into account a variety of factors including different communication paramete...

Страница 35: ...eger corresponds to a byte such as 10 110 50 101 Subnet Mask Mask is corresponding 32 bits number of IP address Some are 1 the others are 0 These 1 and 0 can be combined arbitrary in principle but the...

Страница 36: ...anges in the dynamic IP address it is reported that its own IP address which allows the user to know the new IP address of the device Server Address Need to report to the top of the host IP Server Por...

Страница 37: ...ty Configuration Web interface as shown below Figure 6 6 1 After disabling the corresponding setting function the user will not be able to access the system to the system to set up the interface or to...

Страница 38: ...net Mask dotted decimal format Note the subnet mask is used to determine the IP address range that can be affected by the rule Cases 192 168 1 1 255 255 255 255 the impact of a single IP address 192 1...

Страница 39: ...Edit to make the following window edit Figure 6 6 5 Enterprises are often required to monitor the device s administrator and system or network administrator is the two roles its authority to separate...

Страница 40: ...the password is correct Please remember user name and password after you modify them if forget it please use DEF button to do factory default after do that user name and password will be admin 6 7 St...

Страница 41: ...Figure 6 8 1 Module No more than 18 bytes allow Chinese character English character digit and _ but do not allow space Name No more than 18 bytes allow Chinese character English character digit and _...

Страница 42: ...nfiguration in future 3 Upload configuration files Knock Browse button choice the correct cfg file and knock upload after confirm configuration information in cfg file uploaded to device automatic and...

Страница 43: ...e 6 8 3 System Logout Click the Start button the interface would be returned to the login screen configuration does not have to be changed Device Reboot Click the Reboot button is confirmed the device...

Страница 44: ...get help in the following ways Internet service Make a call to our technical office Return or replace product 7 1 Internet Service Please visit http www 3onedata com 7 2 Make a call to our technical o...