Version 7.0
101
Performance Monitoring and Alarms
Performance Monitoring and Alarms
3. Alarms
3.4.6
Feature Key Related Error
Feature Key Related Error
Description
Feature key error
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.6
3.4.7
Gateway Administrative State Changed
Gateway Administrative State Changed
Description
The administrative state of the gateway has been changed to a new
state.
Note that all state changes are instigated by the parameter
acgwAdminState.
Time limit set in the parameter acgwAdminStateLockControl -
'GateWay shutting down. Max time to LOCK %d sec'
No time limit in the parameter acgwAdminStateLockControl -
'GateWay is shutting down. No time limit.'
When reaching lock state - 'GateWay is locked'
When the gateway is SET to unlocked - 'GateWay is unlocked (fully
active again)'
SNMP Alarm
acgwAdminStateChange
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Alarm Title
Administrative State Change
Alarm Type
Equipment Alarm
Alarm Source
Probable Cause
Other
Severity
Major
Major
Major
Cleared
Additional Info1,2,3
NULL
Corrective Action
A network administrator has taken an action to lock the device. No
corrective action is required.